<LOGO>
FM Transmitter Measurement Report
Created: 2024-07-26 05-52-25
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.20 MHz 5/5, 53 dBuV
Pilot RDS Phase Difference
7.1 kHz 0.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
11 kHz 14 kHz 16984 0,0000
Modulation Power
Limit Measuring Tolerance
11,0 dBr 0,2 dBr
MIN AVE MAX % above 11,2 dBr
-7,2 dBr -7,20 dBr -7,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" " 0000 0 (No PTY) 0 0 0 0 --:--
RT
-
AF EON
-
FM Scope Station: 89.20 MHz, signal: 5/5 (53 dBuV) Max at: 14 kHz MIN: 11 kHz % above 75 kHz: 0,0000 Acquired: 2024/07/26 5:51:22 Total samples: 16984 Equivalent time: 0:14:09 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000 6000
FM Scope MAX: -7,2 dBr MIN: -7,2 dBr AVE: -7,20 dBr % above 11,2 dBr: 0,0 Last value: -7,2 dBr (2024/07/26 5:51:21) Station: 89.20 MHz, signal: 5/5 (53 dBuV) 05:40 05:42 05:44 05:46 05:48 05:50 0 50 100 Dev. MAX [kHz] -5 0 Pm [dBr] 0 5 Signal Quality